INSPECTOR®
4000 General Specifications
Analysis
- Scan Reflectance Profile per ANSI
Guideline for Bar Code Print Quality
- Incorporates the latest AIAG and UCC
requirements
- Traditional Verification Method
- Scan Profile Analysis
Parameters Analyzed
- ANSI Scan Reflectance Profile
parameters: Decodability, Symbol Contrast, Reflectance
(min/max), Edge Contrast (min/max), Modulation, Defects,
Application Compliance
- Traditional parameters: PCS, Ratio,
Encodation Check, Mod Check, Average Bar Width Deviation
Symbologies
- ANSI
- AIAG B1, B3/B4/B5, B10*
- Code 39 with Mod 43
- HIBC
- LOGMARS
- Version A & E, 2 or 5 digit
addendum
- 8 & 13 with 2 or 5 digit
addendum
- Interleaved 2 of 5 (I 2 of 5):
- Code 93: ANSI
- Codabar: ANSI
- Subsymbologies menu selectable
Features
- Auto-discrimination between
symbologies
- Four menu selectable aperture sizes
- Two menu selectable light wavelengths
- Store and print capability
- Multiple scan averaging
- Traditional & Scan Reflectance
Profile analysis printout without need of special mode
settings
- Computer interface mode
- Bi-directional scanning
Auto-Optic Scan Head
- Two aperture configurations each with
four aperture sizes:
- 3,5,10, and 20 mil or 3,6,10, and
20
- Two light wavelengths: 660 and 925nm
User Interface
- Simple 4 button operation: On, Print,
Select, Enter
- 32 character alphanumeric LCD displays
all symbol analysis results, low battery warning and user
interface functions
- Five indicator LEDs indicate ANSI
overall symbol grade
- Audible tones indicate pass/fail
results and low battery warning
Optional Accessories
- Printer (supports Scan Reflectance
Profile graphics)
- Battery charger
- Nicad rechargable batteries (4 per
pack) '
- RS-232 interface cable
Dimensions
- Size: 7.8" (198.1mm)L x
4.6"(116.8mm)W x 1.9" (48.3mm)H
- Weight; 32oz. (907.2g)
Specifications subject to
change without notice
- Sample
Printout
- Overview
- Copyright
©1997 - 2002 Data Identification Systems All Rights
Reserved
- Last